首页> 外文会议>Computational Intelligence and Industrial Application, PACIIA, 2008 Pacific-Asia Workshop on >Relative Accuracy Test Audit Evaluation for Flue Gas Continuous Emission Monitoring Systems in Power Plant
【24h】

Relative Accuracy Test Audit Evaluation for Flue Gas Continuous Emission Monitoring Systems in Power Plant

机译:电厂烟气连续排放监测系统的相对精度测试审计评估

获取原文

摘要

Continuous Emissions Monitoring Systems (CEMS) permanently installed for selected processes require initial and periodic quality assurance audit tests to ensure that they are functioning properly and reporting emissions accurately. Depending on the industry and process type, there are several sets of regulations that dictate the exact QA/QC requirements that the CEMS must meet. Measurement data by CEMS is a legal base to charge for pollutant emission. But the great masses of CEMS have some problems of high data drift and low measurement accuracy etc. For evaluating CEMS Relative Accuracy, we simultaneously compared SO_2/NOx and Dust monitoring systems with CEMS and normal handmade sampling method at different boiler load. It draws a conclusion that Relative Accuracy Test Audit (RATA) of SO_2/NOx monitoring systems goes beyond criterion. The data should be corrected. Continuous Opacity monitoring systems is exact. CEMS should carry out RATA and Bias Test to ensure measurement data validation and accuracy.
机译:为选定过程永久安装的连续排放监控系统(CEMS)需要进行初始和定期质量保证审核测试,以确保它们正常运行并准确报告排放。根据行业和过程类型的不同,有几套法规规定了CEMS必须满足的确切QA / QC要求。 CEMS的测量数据是收取污染物排放的法律依据。但是,大量的CEMS存在数据漂移高,测量精度低等问题。为了评估CEMS的相对精度,我们同时比较了SO_2 / NOx和粉尘监测系统与CEMS和不同锅炉负荷下的常规手工采样方法。得出结论,SO_2 / NOx监测系统的相对精度测试审核(RATA)超出了标准。数据应予以更正。连续的不透明度监视系统是精确的。 CEMS应进行RATA和偏置测试,以确保测量数据的有效性和准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号