Heart sound, pulse wave and respiration are simultaneously measured with single fiber Bragg grating(FBG) sensor. The FBG sensor is inscribed in optical fiber so that it is quite thinner than conventional electrical sensor, even enough to be weaved in clothes. In this study, single FBG sensor is taped near the Tricuspid area and on the carotid artery with the surgical tape. Measured data is denoised through digital Butterworth filter with low pass filter (0.2 Hz), medium frequency band pass filter (0.5 Hz - 5.0 Hz) and higher frequency bandpass filter (35.0 Hz - 55.0 Hz) to extract the information of respiration, pulse wave and heart sound, respectively. The lower frequency signal follows the reference respiration sensor. The medium and higher frequency signal contains the features of typical pulse wave and heart sound waveform. The pulse wave measured on precordium contains the feature of apex cardiogram. The result also indicate that the timing of the heart sound is slightly delayed on the carotid artery. These results indicate the possibility of wearable, continuous vital sigh measurement system.
机译:使用单光纤布拉格光栅(FBG)传感器可同时测量心音,脉搏波和呼吸。 FBG传感器刻在光纤中,因此比传统的电传感器要薄得多,甚至可以编织在衣服上。在这项研究中,单个FBG传感器用外科手术胶带贴在三尖瓣附近和颈动脉上。测量数据通过带低通滤波器(0.2 Hz)的数字巴特沃斯滤波器,中频带通滤波器(0.5 Hz-5.0 Hz)和高频带通滤波器(35.0 Hz-55.0 Hz)去噪,以提取呼吸,脉搏波信息和心音。较低频率的信号跟随参考呼吸传感器。中高频信号具有典型的脉搏波和心音波形的特征。在前皮层上测得的脉搏波包含心尖图的特征。该结果还表明,心音的定时在颈动脉上稍有延迟。这些结果表明了可穿戴的连续生命叹气测量系统的可能性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号