From the experimental results explained above, the followingconclusions were obtained:1) The maximum strength of both specimens strengthenedby wing walls was significantly increased compared tothat of the control specimen. Moreover, the ductility ofthe specimen FP-W2 was larger than that of the specimenFP-W1.2) Punching shear failure occurred in FP-W1 at themaximum strength, while it was observed after themaximum strength for FP-W2. Shear cracks extendedradially from the column and the surface concrete peeledup due to the punching shear failure.
机译:根据上面解释的实验结果,以下内容 结论: 1)两种试样的最大强度均得到加强 与机翼相比,机翼壁显着增加 对照样品的。而且,延展性 FP-W2标本大于标本 FP-W1。 2)FP-W1的冲切剪切失效发生在 最大强度,而在 FP-W2的最大强度。剪切裂纹扩展 从柱子和表面混凝土上径向剥落 由于打孔剪切失败而损坏。