摘要

In modern power systems with increasing penetration of wind turbines (WTs), improvement of low voltage ride through (LVRT) capability of WTs equipped with doubly-fed induction generators (DFIGs) is an important topic. Thus, this paper proposes an LVRT strategy and compares its performance with a widely used conventional LVRT strategy. The proposed strategy is designed with a capacitor connected in series with an inductor and both are connected in parallel to a resistor. This configuration is then connected to the ac side of the rotor side converter (RSC) via an R-L circuit. To validate the performance of the proposed scheme, three phase fault condition is simulated and analysed. Based on simulation results obtained in MATLAB/Simulink, there is significant improvement achieved in the stated objectives compared to the conventional LVRT scheme.
机译:在具有不断增加的风力涡轮机(WT)穿透力的现代电力系统中,配备双馈感应发电机(DFIG)的WT的低压穿越(LVRT)能力的提高是一个重要的主题。因此,本文提出了LVRT策略,并将其性能与广泛使用的常规LVRT策略进行了比较。所建议的策略是在电容器与电感器串联连接的情况下设计的,两者均与电阻器并联。然后,此配置通过R-L电路连接到转子侧转换器(RSC)的ac侧。为了验证所提方案的性能,对三相故障情况进行了仿真和分析。根据在MATLAB / Simulink中获得的仿真结果,与传统的LVRT方案相比,在所述目标上实现了显着的改进。