In this work, we have used synchrotron X-ray diffraction phasemappingcombined with electrochemistry to examine the operationof an inert anode in a Cambridge-FFC type laboratory cell. Inertanodes usually function via interaction of the anode with theelectrolyte (CaCl_2) and the anode product (O_2). Upon immersion ofan anode in the bath, there is dynamic formation of an insulatingoxide film at the anode surface. Such films must be thin enough toallow electronic conduction, but thick enough to protect the surfacefrom further reaction. Utilising an in-situ energy dispersive X-raydiffraction technique on a custom-built furnace for synchrotronmeasurements incorporating the FFC-type cell, the group is able tomonitor the evolution of such films on the anode and elucidate theeventual failure mechanism of this anode.
机译:在这项工作中,我们使用了同步加速器X射线衍射相位图 结合电化学检查操作 剑桥-FFC型实验室电池中惰性阳极的制备。惰性的 阳极通常通过阳极与阳极的相互作用而起作用。 电解质(CaCl_2)和阳极产物(O_2)。浸入后 浴中的阳极,动态形成绝缘体 阳极表面的氧化膜。这样的膜必须足够薄以至于 允许电子传导,但厚度足以保护表面 从进一步的反应。利用原位能量色散X射线 同步加速器定制炉上的衍射技术 测量结合了FFC型电池,该小组能够 监测阳极上此类膜的演变并阐明 阳极的最终失效机理。