Combined approach to Medium Voltage Cable and Accessories Aging Management Technique at Nuclear Power Plants

机译:核电站中压电缆及附件老化管理技术的组合方法

获取原文

摘要

Studying the influence of long-term operation on mediumvoltage (MV) cable and associated accessoriesperformance is an ongoing process. In the many yearscollecting operating experience at nuclear power plants(NPPs), including at those plants licensed for extendedoperation, it has been found that extruded polymercabling and accessories can be susceptible to degradationwhich in some cases cannot be easily or accuratelyinspected to assess reliability.NPPs have specific nuclear regulatory commitments toestablish programmatic ways to appropriately assess andmaintain aging management of medium voltage cablesand accessories. This paper provides practical NPPexperience, methods, and examples of maintaining acomprehensive test methodology that prevents emergentcable replacement and/or unplanned outages. The twovivid examples depicted in this paper discuss this matureMV cable testing program based on a combination ofcomplementary test methods that enable NPPs to:1. Maximize sensitivity to a broad range of defects2. Minimize the risk of ‘false positive' and ‘falsenegative’ diagnostic results3. Provide high confidence in engineering judgmentsand decisions.The combination of testing techniques provides a solidtechnical basis to support robust ‘Fitness for Service'decisions. The condition monitoring data can be used toidentify time-related deterioration trends before theyaffect cable performance. The overall approach allowsNPPs to make risk-informed and planned decisions ontargeted replacement/repair and to address deficienciesto maintain reliable electrical systems.
机译:研究长期运营对培养基的影响 电压(MV)电缆和相关附件 性能是一个持续的过程。多年来 收集核电厂的运行经验 (NPPs),包括那些获得延期许可的工厂 操作中,发现挤出的聚合物 电缆和配件可能会退化 在某些情况下不容易或不准确 检查以评估可靠性。 核电厂有具体的核监管承诺, 建立计划性方法来适当评估和 维持中压电缆的老化管理 和配件。本文提供了实用的NPP 维护人员的经验,方法和示例 全面的测试方法可以防止出现 电缆更换和/或计划外停机。他们俩 本文中描述的生动例子讨论了这种成熟 基于MV电缆测试程序的组合 使NPP能够执行以下补充测试方法: 1.最大限度地提高对各种缺陷的敏感性 2.最大限度地降低“误报”和“误报”的风险 阴性诊断结果 3.对工程判断高度信任 和决定。 测试技术的结合提供了坚实的基础 支持强大的“健身服务”的技术基础 决定。状态监视数据可用于 识别与时间相关的恶化趋势,然后再进行预测 影响电缆性能。总体方法允许 核电厂对风险做出明智的计划性决策 有针对性的更换/维修并解决缺陷 维护可靠的电气系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号