DEFORMATION BEHAVIOR OF ZIRCALOY-4 CLADDING IN A SPENT FUEL POOL ACCIDENT

机译:燃油池事故中ZIRCALOY-4熔覆的变形行为

获取原文

摘要

Despite the low frequency of events leading to a lossof-cooling function and a loss-of-coolant accident (LOCA)at a spent fuel pool (SFP) and the postulated slow accidentprogression, the potential risk of SFP-LOCA is thought tobe significant owing to the inventory higher than that in thereactor and the lack of containment around the SFP. Todevelop and validate a cladding deformation modelleading to burst based on a realistic SFP-LOCA scenario,burst tests of as-received Zircaloy-4 cladding wereconducted under a wide range of postulated SFP-LOCAconditions. The internal pressure of test rods, the heatingrate and the air ratio in a steam environment were variedin the tests as parameters. The relationship between themeasured shape of the burst opening, circumferential burststrain, burst pressure, burst temperature, burst time andazimuthal difference in the cladding temperature wasdiscussed. The results obtained in this study were alsocompared with the published data obtained from thereactor LOCA conditions.
机译:尽管发生事件的频率较低,导致损失- 冷却功能和冷却液损失事故(LOCA) 在乏燃料池(SFP)和假定的缓慢事故中 进展中,SFP-LOCA的潜在风险被认为是 由于库存量高于 反应堆以及SFP周围缺乏密闭性。到 开发并验证包层变形模型 导致基于现实的SFP-LOCA场景而爆发 Zircaloy-4熔覆层的爆破测试是 在各种假定的SFP-LOCA下进行 情况。测试棒的内部压力,加热 蒸汽环境中的空气速率和空气比变化 在测试中作为参数。之间的关系 测量的爆裂口形状,周向爆裂 应变,爆破压力,爆破温度,爆破时间和 包层温度的方位角差异为 讨论过。在这项研究中获得的结果也是 与从 反应堆LOCA条件。