In order to reduce the common mode (CM) voltage and shaft voltage for induction motor driven by inverter, an Improved Selective Harmonics Elimination Pulse Width Modulation (ISHEPWM) method was proposed in this paper. First ISHEPWM eliminates certain low order components of common mode voltage (CMV) generated by inverter. Secondly the high order components of the CMV were attenuated by a well-designed passive CM filter. Based on a three-level neutral-point-clamped (3L NPC) platform, the experimental results with and without CM filter were analyzed in detail, and the former obtained a much lower CMV and shaft voltage at the motor terminal compared with the latter, which verify the validity of the SHEPWM scheme proposed in this paper.
机译:为了降低变频器驱动的感应电动机的共模电压和轴电压,提出了一种改进的选择性谐波消除脉宽调制(ISHEPWM)方法。首先,ISHEPWM消除了由逆变器生成的某些低阶共模电压(CMV)分量。其次,通过精心设计的无源CM滤波器可以衰减CMV的高阶分量。基于三电平中性点钳位(3L NPC)平台,详细分析了带和不带CM滤波器的实验结果,与前者相比,前者获得的电动机端电压和轴电压要低得多,验证了本文提出的SHEPWM方案的有效性。