A combined system consisting of a passive filter and a small-ratedactive filter that are connected in series is discussed as a method ofovercoming power system harmonic interferences caused byharmonic-producing loads such as diode or thyristor converters andcycloconverters. The system features filtering characteristicsindependent of the source impedance, parallel and series resonancebetween the source and the passive filter that is dumped by the activefilter, and a required rating of the active filter which is much smallerthan that of a conventional active filter. Experimental results obtainedfrom a prototype model are shown to verify the developed theory
机译:由无源滤波器和小功率滤波器组成的组合系统 作为一种方法,讨论了串联连接的有源滤波器。 克服由电力系统引起的谐波干扰 产生谐波的负载,例如二极管或晶闸管变流器以及 循环转换器。该系统具有过滤特性 与源阻抗无关,并联和串联谐振 在源和有源滤波器转储的无源滤波器之间 滤波器,以及所需的有源滤波器额定值要小得多 比传统的有源滤波器要好。获得实验结果 展示了原型模型中的数据以验证已开发的理论