DIII-D tokamak will be operated at higher magnetic flux and longer pulse lengths starting in 2006. Hence the water-cooled copper coils will be subjected to higher currents and longer pulse length. In order to insure that the coils do not overheat during such an operating condition, a systematic program of analysis and experiments is being implemented. F8A coil has been operated with limited I2t, due to its long cooling path and limited coolant flow rate. The geometry of this coil was modeled which accounted for the forced convective heat transfer to the coolant, conduction heat transfer between the windings, heat loss to the atmosphere and change in coolant temperature as a function of distance. The model was used to determine the flow rate required and time to cool down the coil for higher currents and longer pulse operation without exceeding the safe temperature limits
机译:从2006年开始,DIII-D托卡马克将在更高的磁通量和更长的脉冲长度下运行。因此,水冷铜线圈将承受更高的电流和更长的脉冲长度。为了确保线圈在这种工作条件下不会过热,正在实施系统的分析和实验程序。 F8A线圈的冷却路径较长且冷却剂流量有限,因此只能在有限的I 2 t下运行。对该线圈的几何形状进行了建模,考虑了到冷却剂的强制对流热传递,绕组之间的传导热传递,到大气的热损失以及冷却剂温度随距离的变化。该模型用于确定所需的流量和冷却线圈所需的时间,以便在不超过安全温度限制的情况下获得更高的电流和更长的脉冲运行时间