The Sizewell B nuclear power station primary protection system(PPS) is classified as 1E. Safety class 1E defines electric equipmentand systems that are essential to emergency reactor shutdown,containment isolation, reactor core cooling and containment and reactorheat removal or otherwise are essential in preventing significantrelease of radioactive material to the environment. Here, the authorsdescribe how, for qualification of the PPS it was required todemonstrate that the equipment would perform its safety functions duringabnormal environment extremes and during and after a safe shutdownearthquake event
机译:Sizewell B核电站一次保护系统 (PPS)被分类为1E。安全等级1E定义了电气设备 和对反应堆紧急关闭必不可少的系统, 安全壳隔离,反应堆堆芯冷却以及安全壳和反应堆 散热或其他方式对于防止显着影响至关重要 向环境释放放射性物质。在这里,作者 描述如何对PPS进行资格鉴定 证明设备将在以下过程中执行其安全功能 异常的极端环境以及安全关机期间和之后 地震事件