Mobile disconnect switches allow electrical isolation on high voltage transmission lines where stationary switches are not available, or special switching is required. In particular, dropping/picking part of a line and loop switching are two key applications of mobile switches. These switches are used in live-line environment. Therefore, several worker safety considerations must be taken into account prior to their deployment. Electrical clearance, grounding design, switch duty calculation and switching sequence - all needs to be assessed. This article provides a set of simplified methods for initial calculations, and an example of real-world deployment where many of these issues are addressed.