首页> 外文会议>Conference on Precision Electromagnetic Measurements >AC-DC Difference Measurement of 792A at Millivolt Voltage
【24h】

AC-DC Difference Measurement of 792A at Millivolt Voltage

机译:毫伏电压下792A的AC-DC差值测量

获取原文

摘要

The ac-dc difference of the ac-dc transfer standard fluke 792A has been calibrated at millivolt voltage in this paper. The 792A is calibrated based on the voltage divider techniques. A cascaded inductive voltage divider (IVD) has been built with using binary inductive voltage dividers (BIVDs) in cascade connection. The ratio errors of the cascaded IVD are calibrated against the self-calibrated BIVD at millivolt voltages. A resistive voltage divider (RVD) which has equal ratio with the cascaded IVD has also been built. The dc and ac ratio errors at low frequencies are consistent. The VDs can trace the small voltages to the thermal voltage converter (TVC) and be used to measure the ac-dc difference of the 792A at mV ranges.
机译:本文已在毫伏电压下校准了交流-直流传输标准Fluke 792A的交流-直流差异。 792A是基于分压器技术进行校准的。已通过在级联连接中使用二进制电感分压器(BIVD)来构建级联电感分压器(IVD)。级联IVD的比率误差相对于自校准BIVD在毫伏电压下进行了校准。还建立了与级联IVD具有相等比率的电阻分压器(RVD)。低频下的直流和交流比率误差是一致的。 VD可以将较小的电压跟踪到热电压转换器(TVC),并用于测量792A在mV范围内的ac-dc差。