This paper describes the comparison of amplitude error measurement in current shunts between NMIA and NIM at frequencies from 1 kHz to 100 kHz. A set of cage design shunts has been developed at NMIA and its amplitude errors determined using the ac-dc transfer setup at NMIA. At NIM a set of Inductive Current Dividers (ICDs) with ratios of 2:1, 5:1 and 10:1 has been developed to compare the amplitude errors of two shunts. Based on two totally different measurement methods, a number of current shunts have been compared at frequencies from 1 kHz to 100 kHz. The measurements of amplitude errors of current shunts yield excellent agreement within $10 mu mathrm{Omega}/mathrm{Omega}$ at frequencies up to 100 kHz and currents from 0.5 A to 10 A.
机译:本文介绍了NMIA之间电流分流器中的幅度误差测量的比较,频率为1 kHz至100kHz。在NMIA开发了一组笼式设计分流器,并且在NMIA下使用AC-DC转移设置确定的幅度误差。在NIM的一组电感电流分隔器(ICD),比率为2:1,5:1和10:1,以比较两个分流器的幅度误差。基于两个完全不同的测量方法,已经在1 kHz至100 kHz的频率下比较了许多当前分流器。当前分流器的幅度误差的测量产生了很好的协议 $ 10 \ \ mu \ mathrm { \ omega} / \ mathrm {\ omega} $ 在高达100 kHz的频率和0.5 A至10 A的电流。