首页> 外文会议>Conference on Precision Electromagnetic Measurements >Performance Study of a Digital Impedance Bridge on the basis of Capacitance Measurements in Audio Frequency
【24h】

Performance Study of a Digital Impedance Bridge on the basis of Capacitance Measurements in Audio Frequency

机译:基于音频电容测量的数字阻抗电桥性能研究

获取原文

摘要

A digitally assisted coaxial bridge—mainly consisted of a ratio transformer and digital voltage sources—was set up in a 4-terminal-pair (4-TP) configuration for the precision capacitance measurements. The 10: 1 capacitance ratio was measured in the range of 1 pF $sim 1 mumathrm{F}$ mainly at 1 kHz using the 4-TP bridge. The measurement results show a degree of equivalence from a few parts in 108 to 105 when compared with those obtained using 2-terminal-pair/3-terminal bridges. Moreover, the measurement frequency of the 4-TP bridge was varied from 50 Hz to 20 kHz. The Allan deviation measurements imply that the statistical uncertainty could be achieved a level of 10−9 at 1 kHz.
机译:数字辅助同轴桥(主要由比率变压器和数字电压源组成)以4端子对(4-TP)配置进行设置,以进行精确的电容测量。在1 pF的范围内测量了10:1的电容比 $ \ sim 1 \ \ mu \ mathrm {F} $ 使用4-TP电桥主要在1 kHz时。测量结果显示出十分之一的等效程度 8 至10 5 与使用2端对/ 3端桥获得的结果相比。此外,4-TP电桥的测量频率在50 Hz至20 kHz之间变化。艾伦偏差测量表明统计不确定性可以达到10级 -9 在1 kHz下