Comparison of Power Quality Improvement between 3P2L VSI and Cascaded H-Bridge 3L Inverter Based Dual DSTATCOM

机译:基于双DSTATCOM的3P2L VSI和级联H桥3L逆变器的电能质量改善比较

获取原文

摘要

This paper is about power quality improvement which analyse the comparison between 3P2LVSI (voltage source inverter) and cascaded H-bridge 3L inverter based dual distributed static compensator (DSTATCOM). For these topologies the operation of DSTATCOM is providing the switching pulses by using instantaneous symmetrical component theory (ISCT) along with PI controller. The comparative analysis is to select the particular level used for power quality improvement within distribution system. Both the topologies are use to control the ISCT controller algorithms which are use to formulated on the basis of a mathematical equations by using MATLAB/Simulink. In comparison with the 3P2L VSI and cascaded H-bridge3L inverter based dual distributed static compensator (DSTATCOM) demonstrates more power quality improvements and DC link capacitor voltage, voltage balancing, and source current distortion of harmonic reduction under at the disturbance influence caused by at the balanced nonlinear load condition.
机译:本文针对电能质量的改进,分析了3P2LVSI(电压源逆变器)与基于双分布式静态补偿器(DSTATCOM)的级联H桥3L逆变器之间的比较。对于这些拓扑,DSTATCOM的操作通过使用瞬时对称分量理论(ISCT)和PI控制器来提供开关脉冲。比较分析是选择用于配电系统中电能质量改善的特定级别。两种拓扑结构均用于控制ISCT控制器算法,这些算法可通过使用MATLAB / Simulink在数学方程式的基础上进行公式化。与基于3P2L VSI和级联H桥3L逆变器的双分布式静态补偿器(DSTATCOM)相比,展示了更多的电能质量改善和直流链路电容器的电压,电压平衡以及源极电流畸变在谐波干扰下对谐波降低的影响。平衡的非线性负载条件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号