Recently, in the frame of the EUROSTAR research project entitled "Building Insulation against Outdoor Vibrations" (BIOVIB), a test bench has been developed in CDM laboratory to determine the isolation performance of Building Base Isolation (BBI) systems. The test bench consists of three main parts: (1) a superstructure, (2) isolation bearings and (3) a substructure (foundation). The superstructure consists of a concrete column and four steel blocks being hanged from the column by four springs to represent the effect of floors resonance frequencies. The substructure (foundation) is a thick steel plate supported by four thin pads adjusted to dynamically behave as a real foundation. In this test bench, the isolation efficiency can be directly determined as the difference between the vibration level at the superstructure in a non-isolated build-up and that obtained in an isolated one. However, in practice, such a direct comparison between the isolated and non-isolated building cannot be undertaken. Using an isolated and a non-isolated setup, the performance of a BBI system (CDM-SEB) has been evaluated. Finally, the performance of the system in terms of the insertion loss has been compared with that obtained by an insertion gain indicator defined in terms of the isolator transmissibility and the superstructure and substructure mobilities. Results show a reasonable agreement between the proposed insertion gain indicator and the direct insertion gain obtained from the measurement in the test bench.
机译:最近,在EUROSTAR研究项目名为“抵抗室外振动的建筑物隔热”(BIOVIB)的框架内,已在CDM实验室中开发了一个测试台,以确定建筑物基础隔离(BBI)系统的隔离性能。测试台包括三个主要部分:(1)上部结构,(2)隔离轴承和(3)下部结构(基础)。上层建筑由一个混凝土柱和四个由四个弹簧悬挂在柱上的钢块组成,代表地板共振频率的影响。下部结构(基础)是一块厚钢板,由四个薄垫支撑,这些薄垫经过调整以动态地表现为真实的基础。在该试验台中,隔离效率可以直接确定为非隔离建筑中上部结构的振动水平与隔离建筑中的振动水平之差。但是,实际上,不能在隔离的建筑物和非隔离的建筑物之间进行这种直接比较。使用隔离的和非隔离的设置,已评估了BBI系统(CDM-SEB)的性能。最后,将系统在插入损耗方面的性能与通过隔离器的透射率以及上部结构和下部结构的活动性定义的插入增益指标获得的性能进行了比较。结果表明,建议的插入增益指示器与从测试台中的测量获得的直接插入增益之间存在合理的一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号