Centralized Post Paid Water Meter Controller Using Wireless Sensor Network

机译:使用无线传感器网络的集中式付费后水表控制器

获取原文

摘要

Conventional monitoring and termination system in Indonesia’s water company is done by direct inspection to each customer’s house. With the number of customers reaching 160,604, this system is no longer effective and efficient. In order to support the increasing needs of population, new technology is needed to centralized monitoring and controlling system. In this paper, we proposed the implementation of wireless sensor network (WSN) for centralized valve control in the form of digital water meter. The implementation uses water flow sensor to calculate water discharge, solenoid valve as valve controller, and LoRa SX1278 as communication between node and sink node. Results shown that the calculation of our proposed work is valid proved by sensor accuracy that reached 99,035%. Data transmission that used single-hop routing LoRa SX1278 showed 95% accuracy in 10 meters distance and 77% in 200 meters. Average time to communicate between node and concentrator is 1.0086 seconds while from concentrator to each node is 0.8818 seconds.
机译:印尼自来水公司的常规监控和终止系统是通过直接检查每个客户的房屋来完成的。随着客户数量达到160604,该系统不再有效。为了支持不断增长的人口需求,需要新技术来集中监控系统。在本文中,我们以数字水表的形式提出了用于集中式阀门控制的无线传感器网络(WSN)的实现。该实现使用水流传感器计算出水量,电磁阀作为阀控制器,LoRa SX1278作为节点与接收器节点之间的通信。结果表明,通过传感器精度达到99,035%,可以证明我们提出的工作的计算是有效的。使用单跳路由LoRa SX1278的数据传输在10米距离内显示95%的精度,在200米距离内显示77%的精度。节点与集中器之间的平均通信时间为1.0086秒,而从集中器到每个节点的平均通信时间为0.8818秒。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号