The accidental reversal installation of an orifice plate could occur during maintenance operations and a long time may have elapsed before being noticed. The reversal installation can result in a significant mismeasurement of flow in a pipe. In the paper, a computational fluid dynamics (CFD) model has been developed to simulate the pressure and velocity distribution in a pipe with the correct and the reversed installation of an orifice plate. The results shown that there is a significant difference between the correct and reversed installation in terms of pressure. Using the CFD pressure drop results for flows in both installations, an estimate correlation between those installations was found. This result provides the method to solve the issue about the accidental reversal of an orifice plate using a correction factor.
机译:孔板的意外颠倒安装可能会在维护操作期间发生,并且可能经过很长时间才引起注意。反向安装会导致管道中流量的严重错误测量。在本文中,已经开发了计算流体动力学(CFD)模型,以正确安装和反向安装孔板来模拟管道中的压力和速度分布。结果表明,正确安装和反向安装之间在压力方面存在显着差异。使用两个设备中流量的CFD压降结果,可以发现这些设备之间的估计相关性。该结果提供了使用校正因子来解决关于孔板的意外反转的问题的方法。