In this paper a new algorithm based on phasor measurements for estimating the The?venin Equivalent (TE) and system inertia constant is proposed. The method estimates the network TE seen from a generator terminal and equivalent system inertia constant by means of phasor data that is available at Phasor Data Concentrator (PDC) center. It is shown that the parameters of the TE could be estimated at any system condition, but the value of system inertia constant is available only after some disturbances. The algorithm is tested on a standard Nine-Bus test system in different conditions. Results show that this method can efficiently estimate the TE both in steady-state and transient conditions as well as system inertia constant.
机译:在本文中,提出了一种基于Phasor测量的新算法,用于估计ΔVenin等效(TE)和系统惯性常数。该方法估计从发电机终端和等效系统惯性常量通过相位数据集中器(PDC)中心可用的相量数据来恒定的网络TE。结果表明,TE的参数可以在任何系统条件下估计,但系统惯性常量的值仅在一些干扰之后可用。该算法在不同条件下的标准九个总线测试系统上进行了测试。结果表明,该方法可以在稳态和瞬态条件下有效地估算TE以及系统惯性恒定。