Influence of Ambient Humidity on PDIV and Endurance of Inverter-fed Motor Insulation

机译:环境湿度对变频调速电动机绝缘的PDIV和耐久性的影响

获取原文

摘要

This work aims to report the influence of ambient humidity on partial discharge inception voltage (PDIV) and lifetime (endurance) of the insulation for inverter-fed motors. The PDIV on polyimide film and rotor bar insulated by NOMEX at sinusoidal voltages with 50 Hz frequency and the endurance tests of inverter-fed motor turn insulation under repetitive unipolar impulsive voltages with 10 ns rise time and 200 ns voltage on-time were performed at four relative humidity (RH), i.e. 40%, 60%, 80%, 95%, controlling the ambient temperature at 50 °C. Experimental results show that both the PDIV and endurance decrease significantly with increasing RH. Accordingly, the influence of ambient humidity on the test results should be carefully considered when performing PDIV and endurance tests on the insulation of low-voltage and high-voltage inverter-fed motors according to IEC standards.
机译:这项工作旨在报告环境湿度对逆变器供电的电动机的局部放电起始电压(PDIV)和绝缘寿命(耐久性)的影响。在40 Hz的正弦电压下,用NOMEX绝缘的聚酰亚胺膜和转子条上的PDIV在4 ns的上升时间和200 ns的导通时间下,在重复的单极脉冲电压下进行了逆变器供电的电机匝绝缘的耐久试验。相对湿度(RH),即40%,60%,80%,95%,将环境温度控制在50°C。实验结果表明,PDIV和耐力都随着RH的增加而显着降低。因此,在根据IEC标准对低压和高压逆变器供电的电机的绝缘进行PDIV和耐久性测试时,应仔细考虑环境湿度对测试结果的影响。