In this work, an isolated small hydro system is dealt with feeding a three-phase 4-wire unbalanced nonlinear loads supported by a battery. A moving average filter-enhanced PLL (MAF-EPLL) control strategy is adapted for extracting fundamental component from load currents. The 4-leg VSC connected to point of common coupling (PCC) is used to control voltage, frequency and to improve the power quality of this system during unbalanced nonlinear loading. The neutral current compensation is provided by using a 4-leg voltage source converter (VSC), which also suppresses the effect of unbalance in a 3-phase 4 wire nonlinear consumer load. This control scheme extracts the amplitude of the load current component corresponding to the fundamental frequency to regulate the generator frequency and to determine the phase angle. The capability of this small hydro system using the presented control strategy is demonstrated through prototype developed in the laboratory.
机译:在这项工作中,一个孤立的小型水力系统要处理由电池支持的三相4线不平衡非线性负载。移动平均滤波器增强的PLL(MAF-EPLL)控制策略适用于从负载电流中提取基本成分。连接到公共耦合点(PCC)的4脚VSC用于控制电压,频率并在不平衡非线性负载期间改善该系统的电能质量。中性点电流补偿是通过使用四脚电压源转换器(VSC)提供的,该转换器还抑制了三相四线非线性用户负载中的不平衡影响。该控制方案提取与基本频率相对应的负载电流分量的幅度,以调节发电机频率并确定相角。通过实验室中开发的原型,证明了使用本文提出的控制策略的小型水电系统的功能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号