Various transformer models can be used to analyze fault conditions occurring in the power system. In this paper, several transformer models and their influence on the fault current course at different types of short circuits are investigated. Therefore, the 3-ph ideal transformer, the 3-ph saturable transformer (with and without saturation consideration), and the label-entered transformer (BCTRAN) were selected to compare the short-circuit current results. Faults such as 1-ph short-circuit, 2-ph metal short-circuit, 2-ph ground short-circuit and 3-ph short-circuit were considered. The results were compared with the methodology given in standard STN EN 60909-0 (33 3020).
机译:各种变压器模型可用于分析电力系统中发生的故障情况。本文研究了几种变压器模型及其对不同短路类型下故障电流过程的影响。因此,选择了3-ph理想变压器,3-ph可饱和变压器(考虑和不考虑饱和)和带有标签的变压器(BCTRAN),以比较短路电流结果。考虑了诸如1-ph短路,2-ph金属短路,2-ph接地短路和3-ph短路之类的故障。将结果与标准STN EN 60909-0(33 3020)中给出的方法进行了比较。