首页> 外文会议>ASME Pressure Vessels and Piping conference >SEISMIC TEST RESULT OF MOTOR-OPERATED BUTTERFLY VALVE ACTUATORS FOR NUCLEAR POWER PLANT
【24h】

SEISMIC TEST RESULT OF MOTOR-OPERATED BUTTERFLY VALVE ACTUATORS FOR NUCLEAR POWER PLANT

机译:核电厂电动蝶阀执行机构的抗震试验结果

获取原文

摘要

Seismic tests were carried out to confirm the operability limit acceleration for a standard motor-operated butterfly valve actuator in three excitation directions. Based on the results, seismic brackets that can operate valves even in three directions at 20×9.8 m/s~2 or more were designed in three representative models. For the model subjected to the seismic test, we mounted the designed seismic bracket and confirmed the operability of the butterfly valve actuator by carrying out vibration tests in three directions at 20×9.8 m/s~2. We used these results and previously reported motor-operated valve actuator seismic test results to creat a revision (draft) of the earthquake resistance evaluation methods.
机译:进行了抗震测试,以确认标准电动蝶阀执行机构在三个激励方向上的可操作极限加速度。根据结果​​,在三个代表模型中设计了即使在三个方向上也能以20×9.8 m / s〜2或更大的速度操作阀门的抗震支架。对于进行了地震测试的模型,我们安装了设计的地震支架,并通过在20×9.8 m / s〜2的三个方向上进行振动测试来确认蝶阀执行器的可操作性。我们使用这些结果以及先前报告的电动阀执行器的抗震测试结果来创建抗震评估方法的修订版(草稿)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号