首页> 外文会议>ASME Pressure Vessels and Piping conference >Effects of Nut thinning due to Corrosion on the Sealing Performance in Bolted Flange Joints under Internal Pressure
【24h】

Effects of Nut thinning due to Corrosion on the Sealing Performance in Bolted Flange Joints under Internal Pressure

机译:腐蚀导致螺母变薄对内压螺栓法兰接头密封性能的影响

获取原文

摘要

In the damage evaluation (and analysis) of the bolted flange joints, it is most important to evaluate the reduction in the sealing performance. Although the marginal nut height found by Alexander's theory [ 1 ] serves as a value smaller about 20% than standard nut height, even if it becomes thin 20% or more on a track record and experience, leakage does not occur. In this study the effects of nut thinning due to corrosion on the sealing performance in 3-inch bolted flange joints under internal pressure by use of FEM calculations. The following results are obtained the relationship between stripping bolt load and nut height is developed, and the marginal nut height for the sealing performance is calculated.
机译:在螺栓法兰接头的损伤评估(和分析)中,最重要的是评估密封性能的下降。尽管亚历山大理论[1]得出的边际螺母高度的值比标准螺母高度小约20%,但即使在以往的记录和经验中变薄了20%或更多,也不会发生泄漏。在这项研究中,通过有限元计算,在内部压力下,因腐蚀导致螺母变薄对3英寸螺栓法兰接头的密封性能的影响。得到以下结果,得出了脱模螺栓载荷与螺母高度之间的关系,并计算了用于密封性能的边际螺母高度。