Statistical evaluation of the periodically sampled method for efficient measurement of the distortions in hyperspectral imager

机译:对高光谱成像仪中畸变进行有效测量的定期采样方法的统计评估

获取原文

摘要

A series of measurements of keystone and smile is required to assemble and aligning hyperspectral imagers. An efficient measurement method was proposed to calculate the keystone and the smile in a single measurement image by implementing an additional tool called the Field Identifier (FI) [1]. The measurement method is simple enough to make it possible to measure the wave front error (WFE) making minimum change from each measurement setup. To evaluate the accuracy of the measurement method, the positional data of 380 points were collected and 3a was calculated along spectral and spatial axis. The measurement error calculated as 3a is to be less than 1/10 of the performance goal to prove the effectiveness of the measurement method.
机译:组装和对准高光谱成像仪需要进行一系列的梯形和微笑测量。提出了一种有效的测量方法,该方法可通过实现称为场标识符(FI)[1]的附加工具来计算单个测量图像中的梯形失真和笑容。测量方法非常简单,可以测量波前误差(WFE),从而使每个测量设置的变化最小。为了评估测量方法的准确性,收集了380个点的位置数据,并沿光谱和空间轴计算了3a。计算为3a的测量误差应小于性能目标的1/10,以证明该测量方法的有效性。