首页> 外文会议>SPIE Medical Imaging Conference >3D printed anthropomorphic physical phantom for mammography and DBT with high contrast custom materials, lesions, and uniform chest wall region
【24h】

3D printed anthropomorphic physical phantom for mammography and DBT with high contrast custom materials, lesions, and uniform chest wall region

机译:3D打印的拟人化人体模型用于乳房X线照相术和DBT,具有高对比度的定制材料,病变和统一的胸壁区域

获取原文

摘要

Anthropomorphic breast phantoms mimic anatomy to evaluate the performance of clinical mammography and digital breast tomosynthesis (DBT) systems. Our goal is to make a phantom that mimics clinically relevant appearance of a patient to allow for improved imaging systems and lesion detection. We previously presented a voxelized 3D printed physical phantom with breast tissue anatomy and a uniform chest wall for evaluating standard QC metrics. In the current study, metal ink resolution patterns were designed for the uniform chest wall spanning 1.5 to 10 lp/mm to cover the resolution range of mammography and DBT systems, and including test objects and fiducial markers for future automated processing. The previous phantom had a limited range of 36%-64% breast density using the commercial photopolymer inks TangoPlus and VeroWhite. Several doped materials were tested with the aim of increasing the contrast of the fibroglandular breast tissue in the previous phantom. We created custom-made photopolymers doped with several materials, including tungsten, to increase breast density, as well as iodine to simulate contrast-enhanced lesions. We also measured a new, commercial photopolymer ink, VeroPureWhite, which corresponds to 92% breast density. The tungsten-doped material allows for 33-100% breast density range in the phantom, more than double the density range in our previous phantom. To our phantom with normal anatomy, we also added lesion inserts in the form of 3D-printed mass lesions with varying sizes and contrasts and uniform, commercially produced iodine inserts to investigate interactions of lesions without and with contrast in breast tissue.
机译:拟人化的人体模型模拟解剖结构,以评估临床乳腺X线摄影和数字化胸部断层合成(DBT)系统的性能。我们的目标是制造一种能够模仿患者临床相关外观的体模,以改善成像系统和病变检测。我们之前曾介绍过一种体素化的3D打印体模,具有乳腺组织解剖结构和统一的胸壁,用于评估标准QC指标。在当前的研究中,金属油墨的分辨率模式是为均匀的胸壁设计的,范围为1.5至10 lp / mm,以覆盖乳房X线照片和DBT系统的分辨率范围,并包括测试对象和基准标记,以便将来进行自动处理。使用市售的光敏聚合物墨水TangoPlus和VeroWhite,以前的幻影的乳房密度范围有限,为36%-64%。测试了几种掺杂材料,目的是增加先前体模中纤维腺乳腺组织的对比度。我们创建了掺有多种材料的定制光敏聚合物,其中包括钨,以增加乳房密度,以及碘,以模拟增强对比的病变。我们还测量了一种新型的商用光敏聚合物墨水VeroPureWhite,它对应于92%的乳房密度。掺钨材料允许人体模型中的乳房密度范围为33-100%,是我们先前人体模型中密度范围的两倍以上。对于具有正常解剖结构的人体模型,我们还以3D打印的肿块形式添加了病灶插入物,其大小和对比度各不相同,并使用商品化的均匀碘插入物来研究在乳腺组织中没有或有造影剂的病灶之间的相互作用。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号