摘要

A method for fast line outage detection and identification in partially observed PMU networks is presented. It is suitable for application to voltage stability analysis that uses the full network topology, and its chief advantage is that it detects outages using limited PMU measurements. It relies on applying measured system states to a pre-outaged network, and detecting an outage by observing nodal injection errors. It then defines a subnetwork surrounded by observed border buses and proceeds to carry out a search within the subnetwork to identify the outaged element. The method was tested on the IEEE39-bus through simulation and yields accurate identifications with times comparable to PMU assisted topology detection in fully observed networks.
机译:提出了一种在部分观测的PMU网络中进行快速断线检测和识别的方法。它适用于使用完整网络拓扑的电压稳定性分析,其主要优点是可以使用有限的PMU测量来检测中断。它依赖于将测得的系统状态应用于预先中断的网络,并通过观察节点注入错误来检测中断。然后,它定义了一个由观察到的边界总线围绕的子网,并继续在该子网内执行搜索以识别出故障的组件。该方法已通过仿真在IEEE39总线上进行了测试,可在完全观测的网络中以与PMU辅助拓扑检测相当的时间获得准确的标识。