Project experiences and studies have indicated that Type 3 and Type 4 wind turbines that integrated to compensated grids or weak AC networks are susceptible to sub synchronous oscillations. This paper investigate the sub and super oscillations of type 4 based wind farms integrated to series compensated transmission systems. The state space model of PMSG based wind farms interfaced with compensated AC networks is established first, then modal analysis and participation analysis are conducted to delve into the interactions between type 4 wind turbines and compensated grid. The results show that the sub and super oscillations are caused by interaction between type 4 converters and compensated transmission system on the condition that the compensation level is high enough. A detailed PSCAD/EMTDC model is applied to validate the results.
机译:项目经验和研究表明,与补偿电网或弱AC网络集成在一起的3型和4型风力发电机容易受到次同步振荡的影响。本文研究了集成到串联补偿传输系统中的基于4型风电场的子振荡和超级振荡。首先建立了基于PMSG的风电场与补偿AC网络相接的状态空间模型,然后进行了模态分析和参与分析,以研究4型风力发电机与补偿电网之间的相互作用。结果表明,在补偿水平足够高的情况下,子振荡和超级振荡是由4型转换器和补偿传输系统之间的相互作用引起的。应用了详细的PSCAD / EMTDC模型来验证结果。