首页> 外文会议>International Institute of Refrigeration (Institut International du Froid;IIR conference on phase-change materials and slurries for refrigeration and air conditioning >ENVIRONMENT-FRIENDLY REFRIGERATION PACKS FOR INDIAN SUPERMARKETS: EXPERIMENTAL INVESTIGATION OF ENERGY PERFORMANCE OF A MULTIEJECTOR-DRIVEN R744 INTEGRATED COMPRESSOR RACK
【24h】

ENVIRONMENT-FRIENDLY REFRIGERATION PACKS FOR INDIAN SUPERMARKETS: EXPERIMENTAL INVESTIGATION OF ENERGY PERFORMANCE OF A MULTIEJECTOR-DRIVEN R744 INTEGRATED COMPRESSOR RACK

机译:印度超级市场的​​环保型制冷包:多喷头驱动的R744一体式压缩机机架的能源性能的实验研究

获取原文

摘要

An integrated CO_2 refrigeration facility is designed for hot climate conditions to improve the basic knowledge of the CO_2 refrigeration in India, especially in the supermarket sector. The operational modes can be adapted to simulate different applications as well as the gas cooler outlet temperature can be regulated to simulate various ambient conditions. For Southern India, a parallel compression configuration with ejectors for expansion work recovery is the most efficient mode (mode 4). It can deliver freezing, refrigeration and air conditioning loads, and has a heat reclaim option. The different operation configurations help to understand the behavior of CO_2 refrigeration for a wide range of applications as well as reveal the respective influences between components. A first test phase running mode 4 for an ambient temperature of 46°C and various receiver pressures in a range of 44 bar - 50bar, proves the feasibility of R744 transcritical systems as a non-HFC based alternative to HCFC-22 in retail applications in countries with high ambient temperature. The CO_2 refrigeration test facility is a preparation and demonstration site for a full-scale replacement of existing commercial refrigeration installations in India.
机译:集成的CO_2制冷设备专为炎热气候条件而设计,以提高印度,尤其是在超市领域中CO_2制冷的基本知识。可以调整运行模式以模拟不同的应用,并且可以调节气体冷却器的出口温度以模拟各种环境条件。对于印度南部,具有用于扩展工作恢复的喷射器的并行压缩配置是最有效的模式(模式4)。它可以提供冷冻,制冷和空调负荷,并具有热量回收选项。不同的操作配置有助于了解CO_2制冷在广泛应用中的行为,并揭示组件之间的各自影响。在46°C的环境温度和44 bar-50bar的各种接收器压力下的第一测试阶段运行模式4证明了R744跨临界系统在零售应用中作为HCFC-22的非基于HFC的替代品的可行性。环境温度高的国家/地区。 CO_2制冷测试设施是一个准备和示范场所,用于大规模替换印度现有的商业制冷设备。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号