首页> 外文会议>IEEE Energy Conversion Congress and Exposition >Voltage Sag Ride-Through Capabilities of Electrolytic Capacitor-less Adjustable Speed Drive System During Power Interruptions
【24h】

Voltage Sag Ride-Through Capabilities of Electrolytic Capacitor-less Adjustable Speed Drive System During Power Interruptions

机译:停电时无电解电容式调速系统的电压暂降能力

获取原文

摘要

Due to thin film capacitor's enhanced reliability and improved input current harmonic performance, adjustable speed drives (ASDs) without using electrolytic dc-link capacitors have been researched extensively in recent years. However, because of thin film capacitor's smaller capacitance per volume, its voltage sag ride-through capabilities are called into question. In this paper, the maximum time duration for an electrolytic capacitor-less ASD system during a power blackout is quantified based on theoretical analysis. An effective voltage sag ride-through method which can achieve maximum hold-up time duration is presented. Experiments are further conducted on a 2.2kW, 380V, 50Hz ASD setup with thin film dc-link capacitor to validate the theoretical analysis.
机译:由于薄膜电容器具有增强的可靠性和改进的输入电流谐波性能,因此近年来对不使用电解直流环节电容器的可调速驱动器(ASD)进行了广泛的研究。但是,由于薄膜电容器的单位体积电容较小,因此其电压跌落穿越能力受到质疑。在本文中,基于理论分析定量了无电解电容器ASD系统在停电期间的最大持续时间。提出了一种有效的电压骤降穿越方法,该方法可以实现最大的保持时间。在带有薄膜直流链路电容器的2.2kW,380V,50Hz ASD装置上进一步进行了实验,以验证理论分析。