Resistive Coupling Effect to Customer Premises Equipment (CPE) due to Non-Equipotential Earthing System

机译:非等电位接地系统对用户房屋设备(CPE)的电阻耦合效应

获取原文

摘要

Even though the International Telecommunication Union-Telecommunication Sector (ITU-T K.21) already imposed on a guideline for over voltages and over currents testing methodology for customer premises equipment, the full adoption of solely on this standard may not be sufficient without taking into account on surge protection devices (SPD) installation and a proper earthing system and bonding configuration as mentioned in ITU-T K.66. There is a high possibility of resistive coupling may occur to the CPE or more specific to a Digital Subscriber Line (DSL) modem when two isolated earthing system that really exists between a distribution point's (DP) earth with that of power utility's earth. Thus, it will create a stray surge current to be discharged indiscriminately which causing a complete circuit within the PCB (printed circuit board) of DSL modem itself as a result of insulation breakdown. Moreover, it is worsened by the presence of lightning-induced surges in multi-pulse via telephone and power cables since neither ITU-T nor International Electrotechnical Commission (IEC) has imposed high priority on these issues.
机译:即使国际电信联盟电信部门(ITU-T K.21)已经对用户端设备的过电压和过电流测试方法实施了准则,但如果不考虑这一点,仅完全采用该标准可能是不够的。考虑了电涌保护设备(SPD)的安装以及ITU-T K.66中提到的正确的接地系统和连接配置。当两个隔离的接地系统确实存在于配电点(DP)的接地与电力公司的接地之间时,CPE或特定于数字用户线路(DSL)调制解调器的电阻耦合的可能性就很高。因此,它将产生杂散的浪涌电流而被不加选择地放电,这会由于绝缘击穿而导致DSL调制解调器本身的PCB(印刷电路板)内的完整电路。此外,由于ITU-T和国际电工委员会(IEC)都没有在这些问题上给予高度重视,因此通过电话和电源线在多脉冲中存在雷电引起的电涌会加剧这种情况。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号