首页> 外文会议>IEEE International Conference on High Voltage Engineering and Application >The On-site Measurement Research of Converter Transformer Harmonic Losses Based on Harmonic Power Source
【24h】

The On-site Measurement Research of Converter Transformer Harmonic Losses Based on Harmonic Power Source

机译:基于谐波电源的换流变压器谐波损耗现场测量研究

获取原文

摘要

HVDC converter transformer is a highly nonlinear transmission of harmonic source, which produces large amounts of harmonic current during the operation. The harmonic losses caused by harmonic current share more than half of converter stations' losses, and affect temperature rise and load capacity of converter transformer. For safe and economic operation of the converter transformer, accurately measuring the converter transformer's harmonic losses has a great significance. This paper propose a method of converter transformer measurement based on harmonic power source by applying the 1/2 rated harmonic current on the AC side of converter transformer. According to comparison of calculation and test result, this paper finds that the calculation method recommended by IEC 61378.2 and GB/T 18494.2 can't give out the accurate harmonic losses of converter transformer. With the test data, this paper gets the harmonic losses' frequency characteristic of converter transformer and the harmonic loss coefficient Kr,h.
机译:HVDC转换器变压器是谐波源的高度非线性传输,在运行过程中会产生大量谐波电流。谐波电流引起的谐波损耗占换流站损耗的一半以上,并且会影响转换器变压器的温升和负载能力。为了使换流变压器安全经济运行,准确测量换流变压器的谐波损耗具有重要意义。本文提出了一种基于谐波电源的变流器测量方法,即在变流器的交流侧施加1/2额定谐波电流。通过对计算结果和测试结果的比较,发现IEC 61378.2和GB / T 18494.2推荐的计算方法不能给出变换器变压器的准确谐波损耗。利用测试数据,得到了换流变压器谐波损耗的频率特性和谐波损耗系数K r,h

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号