首页> 外文会议>IEEE International Conference on High Voltage Engineering and Application >Evaluation Method of Impulse Discharge Performance of Ground Electrode Based on Soil Discharge Image
【24h】

Evaluation Method of Impulse Discharge Performance of Ground Electrode Based on Soil Discharge Image

机译:基于土壤放电图像的接地电极脉冲放电性能评价方法

获取原文

摘要

When impacted by lightning current, the impulse dispersion performance of the grounding device is significantly affected by the dispersion performance of soil near the ground electrode. This effect is mainly reflected by the phenomenon of soil spark discharge. At present, engineers use the empirical formula to convert the soil spark discharge to the impulse coefficient of impulse grounding resistance. Therefore, there is no available quantitative analysis method to evaluate soil impulse dispersion performance. To solve this problem, we present an evaluation method for the impulse discharge efficiency of soil by using X-ray images, define $V_{I}$ as the parameter, which is the volume of discharge region to the ratio of the peak impulse. Then, the rationality and validity of the method are verified. Finally, the variation rules of impulse discharge efficiency are analyzed in different soil. Results show that the $V_{I}$ can reflect the impact of soil medium property on the grounding device impulse discharge efficiency more clearly, and this parameter provides a new idea for enhancing the impulse dispersion performance of soil near the ground electrode.
机译:当受雷电冲击时,接地装置的脉冲色散性能受到接地电极附近土壤的分散性能的显着影响。这种效果主要反映在土火花放电现象。目前,工程师使用经验公式将土壤火花放电转换为脉冲接地电阻的脉冲系数。因此,没有可用的定量分析方法来评估土壤脉冲分散性能。为了解决这个问题,我们通过使用X射线图像来介绍土壤脉冲放电效率的评估方法,定义 $ v_ {i} $ < / tex> 作为参数,其是排出区域的体积与峰值脉冲的比率。然后,验证了该方法的合理性和有效性。最后,在不同的土壤中分析了脉冲放电效率的变化规则。结果表明了 $ v_ {i} $ < / tex> 可以反映土壤介质性质对接地装置的影响更清楚地脉冲放电效率,并且该参数提供了一种提高地电极附近土壤脉冲色散性能的新思路。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号