This paper considers the calibration of Low-Power-Factor wattmeters in high voltage transformer no-load and load loss tests. The value of lowest power factor calibrated is evaluated in consideration of on-site test data and ability of uncertainty evaluation. The harmonic components of both testing current and voltage are measured in the field loss measurement. By analyzing the harmonic components, a nonsinusoidal current with a percentage of 3rd, 5th, 7th harmonic wave is applied for the laboratory calibration of Low-Power-Factor wattmeter in simulation of its on-site tests. There is a voltage unbalance in the field loss measurement. Unbalanced voltage is applied for Low-Power-Factor Wattmeters in comparison with balanced situations. For higher accuracy and resolution, the calibration systems of Low-Power-Factor wattmeters are improved with a nonsinusoidal current and unbalanced voltage standard.
机译:本文考虑了低功率因数Wattmers在高压变压器中的低压变压器,无负载和负载损耗测试。考虑到现场测试数据和不确定性评估能力,评估最低功率因数校准的值。在现场损耗测量中测量测试电流和电压的谐波分量。通过分析谐波分量,施加百分比,第五,第7次谐波的百分比电流用于低功率因子瓦特计的实验室校准,在其现场测试的模拟中。现场损耗测量中存在电压不平衡。与平衡情况相比,低功率因子瓦特计施加不平衡电压。为了更高的精度和分辨率,利用非轴线电流和不平衡电压标准,改善了低功率因子瓦特计的校准系统。