Condition Assessment of Hydrogenerator Stator Bar Insulation Using Partial Discharge Measurements

机译:水轮发电机定子绝缘的局部放电测量。

获取原文

摘要

This paper presents results from laboratory measurements of partial discharge (PD) activity in 50 cm long samples cut from the mainwall section of old hydrogenerator stator bars. All stator bars were manufactured in 1976 and samples were taken after 35 years in service from both the low and high voltage sections of the generator, as well as non-energized back-up bars. The PD activity, using a phase resolved (PRPDA) measuring system, was investigated at different test voltages up to 9.6 kV (1.5 U0), frequencies and temperatures in the range 20–155 °C and 0.1-50 Hz, respectively. The service-aged and the unaged reference samples showed a clear difference in voltage frequency dependence. It was, however, not possible to distinguish between service-aged bars from high and low electric stress. The observed frequency and temperature dependences are discussed with respect to theoretical assumptions regarding possible void degradation and surface conductivity.
机译:本文介绍了从旧氢化机构杆的主体部分切割的50cm长样品中的局部放电(Pd)活性的实验室测量结果。所有定子条在1976年制造,并在从发电机的低压和高压截面以及非通电备用条后使用35倍的样品。使用相位分辨(PRPDA)测量系统的PD活性在高达9.6 kV的不同测试电压下进行研究(1.5 U. 0 ),分别为20-155°C和0.1-50Hz范围内的频率和温度。服务老化和预定参考样本显示出电压频率依赖性的明显差异。但是,它是不可能区分从高电平和低电力应力的服务老化条。关于可能的空隙劣化和表面电导率的理论假设讨论了观察到的频率和温度依赖性。