This study deals with CFD-based optimization of Double Flow Control Devices (DFCDs); a patented technology for enhancing film effectiveness using Taguchi method as a robust optimizing technique. This study adopts offset of the devices with respect to the centerline of the hole, which may happen in the manufacturing process, as a noise factor in the optimizing process. The aim of this study is to explore a possibility of DFCDs to improve the cooling performance of a sophisticated fan-shaped cooling hole called 7-7-7 shaped hole developed by Penn State University [9]. Aerodynamic and thermal performances of the optimized DFCD model were evaluated through the detailed experiments using IR camera and temperature rake.
机译:这项研究涉及基于CFD的双流控制设备(DFCD)的优化。使用Taguchi方法作为强大的优化技术来增强胶片效果的专利技术。这项研究采用了设备相对于孔中心线的偏移(可能在制造过程中发生)作为优化过程中的噪声因素。这项研究的目的是探索DFCD改善宾夕法尼亚州立大学开发的称为7-7-7型孔的复杂扇形冷却孔的冷却性能的可能性[9]。通过使用红外热像仪和温度耙进行的详细实验,评估了优化后的DFCD模型的空气动力学和热性能。