首页> 外文会议>ASME Pressure Vessels and Piping conference >CALCULATION OF AXIAL THERMAL EXPANSION FOR A 1000MW NUCLEAR STEAM TURBINE HIP CASING
【24h】

CALCULATION OF AXIAL THERMAL EXPANSION FOR A 1000MW NUCLEAR STEAM TURBINE HIP CASING

机译:1000MW核电汽轮机缸套轴向热膨胀系数的计算

获取原文

摘要

Steam turbine casing axial thermal expansion is of great significance to the safe operation for nuclear units. Taking a certain 1000MW nuclear steam turbine's HIP casing as an object, this paper calculates the HIP casing absolute axial thermal expansions under such conditions as: steady-state, startup and load shedding. Firstly, a 3D model of the nuclear steam turbine HIP casing is this established by using Pro/E software. Secondly, the heat transfer coefficients of every surface of HIP casing are calculated. Finally, the HIP casing temperature field and the absolute axial thermal expansions under three conditions are calculated and analyzed by using finite element analysis software. The result shows that, the HIP casing axial thermal expansions are 22.642mm and 22.529mm under steady-state condition and startup condition respectively. While, under load shedding condition, minimum axial expansion is 16.202mm and it increases to 22.491mm at rated load.
机译:汽轮机壳体轴向热膨胀对核装置的安全运行具有重要意义。以某某1000MW核电汽轮机的HIP机壳为对象,计算出稳态,启动,甩负荷等条件下的HIP机壳绝对轴向热膨胀。首先,使用Pro / E软件建立了核汽轮机HIP机壳的3D模型。其次,计算了HIP套管每个表面的传热系数。最后,利用有限元分析软件计算并分析了三种条件下的HIP套管温度场和轴向绝对热膨胀。结果表明,在稳态和启动条件下,HIP套管轴向热膨胀分别为22.642mm和22.529mm。而在减载条件下,最小轴向扩展为16.202mm,在额定负载下增加到22.491mm。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号