PURPOSE: Image-guided needle interventions are seldom performed with augmented reality guidance in clinical practice due to many workspace and usability restrictions. We propose a real-time optically tracked image overlay system to make image-guided musculoskeletal injections more efficient and assess its usability in a bed-side clinical environment. METHODS: An image overlay system consisting of an optically tracked viewbox, tablet computer, and semi-transparent mirror allows users to navigate scanned patient volumetric images in real-time using software built on the open-source 3D Slicer application platform. A series of experiments were conducted to evaluate the latency and screen refresh rate of the system using different image resolutions. To assess the usability of the system and software, five medical professionals were asked to navigate patient images while using the overlay and completed a questionnaire to assess the system. RESULTS: In assessing the latency of the system with scanned images of varying size, screen refresh rates were approximately 5 FPS. The study showed that participants found using the image overlay system easy, and found the table-mounted system was significantly more usable and effective than the handheld system. CONCLUSION: It was determined that the system performs comparably with scanned images of varying size when assessing the latency of the system. During our usability study, participants preferred the table-mounted system over the handheld. The participants also felt that the system itself was simple to use and understand. With these results, the image overlay system shows promise for use in a clinical environment.
机译:目的:由于许多工作空间和可用性的限制,很少在临床实践中使用增强现实指导进行图像引导的针头干预。我们提出了一种实时光学跟踪图像叠加系统,以使图像引导的肌肉骨骼注射更加有效,并评估其在床边临床环境中的可用性。方法:由光学跟踪的观察盒,平板电脑和半透明的镜子组成的图像叠加系统,使用户可以使用基于开源3D Slicer应用程序平台的软件实时浏览扫描的患者体位图像。进行了一系列实验,以评估使用不同图像分辨率的系统的等待时间和屏幕刷新率。为了评估系统和软件的可用性,要求五名医疗专业人员在使用覆盖图的同时浏览患者图像,并填写了一份问卷以评估系统。结果:在评估具有不同大小的扫描图像的系统的延迟时,屏幕刷新率约为5 FPS。研究表明,参与者发现使用图像叠加系统很容易,并且发现台式系统比手持系统更加实用和有效。结论:在评估系统的等待时间时,可以确定该系统的性能与大小不同的扫描图像相当。在我们的可用性研究中,与手持设备相比,参与者更喜欢台式系统。与会者还认为该系统本身易于使用和理解。有了这些结果,图像叠加系统就有望在临床环境中使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号