Carbon steel pipelines are provided with corrosion prevention systems, namely an insulating coating and a cathodic protection (CP) system that reduces corrosion rate below 10 µm/a. CP is applied by a stationary cathodic current, which effectiveness on the metal surface is twofold: oxygen consumption and alkalinization (pH > 10) at the metal-to-electrolyte interface. The increase of pH is beneficial, promoting passive condition. In this paper, a preliminary study of the effect of intermittent CP has been carried out in order to investigate the effect of a temporary current interruption on the potential monitoring and on the residual corrosion of the metal. During the on period, oxygen is consumed and alkaline pH is established, during off period, the alkalinity and the slow oxygen replacement assure corrosion rates lower than in free corrosion condition. Test has been performed both in normal and overprotection condition, varying the off period duration, monitoring weekly the protection potential.
机译:碳钢管道设有防腐蚀系统,即绝缘涂层和阴极保护(CP)系统,可将腐蚀速率降低至10 µm / a以下。 CP由固定的阴极电流施加,在金属表面的有效性是双重的:氧消耗和金属与电解质界面处的碱化(pH> 10)。 pH值的增加是有益的,可促进被动状态。在本文中,对间歇性CP的影响进行了初步研究,以研究临时电流中断对电势监测和金属残留腐蚀的影响。在开启期间,氧气被消耗,并且建立了碱性pH值;在关闭期间,碱度和缓慢的氧气置换可确保腐蚀速率低于自由腐蚀条件下的腐蚀速率。已在正常和过度保护条件下进行了测试,改变了关闭时间,并每周监控保护电位。