CATHODIC PROTECTION COUPON USE FOR BURIED PIPING IN PLANT (I.E., COMPLEX) FACILITIES

机译:在工厂(即复杂)设施中使用阴极保护优惠券进行埋管

获取原文

摘要

The measurement and interpretation of cathodic protection (CP) data in plant (i.e., complex) facilities present inherent challenges where mixed metals are electrically continuous with the protected structure. Often there is no attempt to electrically isolate the on-plot buried steel piping networks from the facility for safety and practical considerations. Coupons can be used to assist in the evaluation of CP levels on buried steel piping in mixed-metal circuits. However, the present industry practice of disconnecting the coupon from the mixed-metal circuit to measure the potential and polarization, as described in NACE SP0104-2014 and BS EN 14505:2005, raises concern if the instant-disconnect condition is a true representation of the CP conditions. Another common practice of not interrupting the CP current while measuring coupon-to-soil potentials is also a concern where closely coupled impressed current anode systems are installed adjacent to the buried piping systems. Alternate criteria are often necessary in situations where the polarized -850 millivolt (mV) CSE potential criterion is impractical because of the impact of the buried copper grounding system and other bare metallic structures. Coupons can be used to take advantage of the alternate criteria listed in NACE SP0169-2013 and BS EN 14505:2005. Although coupons provide valuable information in mixed-metal circuits, the data obtained can increase confusion and raise additional questions on the protection status. This paper attempts to address some of the issues and offers a method on how coupons can be used to evaluate the 100 mV polarization criterion in mixed-metal circuits.
机译:在工厂(即复杂的)设施中,阴极保护(CP)数据的测量和解释提出了固有的挑战,其中混合金属与受保护结构在电气上是连续的。出于安全和实际考虑,通常没有尝试将地上的地下埋入式钢管网络与设施电气隔离。优惠券可用于协助评估混合金属回路中埋地钢管上的CP水平。但是,如NACE SP0104-2014和BS EN 14505:2005中所述,将样板从混合金属电路上断开以测量电势和极化的当前行业惯例引起了人们的关注,如果即时断开条件真实地表示了CP条件。在靠近埋管系统的地方安装紧密耦合的外加电流阳极系统时,在测量试样到土壤的电势时不中断CP电流的另一种常见做法也值得关注。由于极化铜埋地系统和其他裸金属结构的影响,在极化-850毫伏(mV)的CSE电势标准不切实际的情况下,经常需要使用替代标准。优惠券可用于利用NACE SP0169-2013和BS EN 14505:2005中列出的替代标准。尽管优惠券在混合金属电路中提供了有价值的信息,但是获得的数据可能会增加混乱,并引起有关保护状态的其他问题。本文试图解决一些问题,并提供了一种方法,该方法可用于在混合金属电路中如何使用样片来评估100 mV极化标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号