首页> 外文会议>IEEE Power and Energy Society General Meeting >Modeling zone-3 protection with generic relay models for dynamic contingency analysis
【24h】

Modeling zone-3 protection with generic relay models for dynamic contingency analysis

机译:使用通用继电器模型对3区保护建模,以进行动态应变分析

获取原文
获取外文期刊封面目录资料

摘要

This paper presents a cohesive approach for calculating and coordinating the settings of multiple zone-3 protections for dynamic contingency analysis. The zone-3 protections are represented by generic distance relay models. A two-step approach for determining zone-3 relay settings is proposed. The first step is to calculate settings, particularly, the reach, of the zone-3 relays individually by iteratively running line open-end fault short circuit analysis; the blinder is also employed and properly set to meet the industry standard under extreme loading conditions. The second step is to systematically coordinate the protection settings of the zone-3 relays. We have developed a tool to automate this approach and generate the settings of all distance relays in a PSS/E format. The calculated zone-3 settings have been tested on a modified IEEE 300 system using a dynamic contingency analysis tool (DCAT).
机译:本文提出了一种凝聚力方法,用于计算和协调用于动态意外事件分析的多个3区保护的设置。 3区保护由通用距离继电器模型表示。提出了一种用于确定区域3中继设置的两步方法。第一步是通过迭代运行线路开路故障短路分析来分别计算3区继电器的设置,特别是范围。在极端的负载条件下,也可以使用遮光罩并将其正确设置以符合行业标准。第二步是系统地协调3区继电器的保护设置。我们开发了一种工具来自动执行此方法,并以PSS / E格式生成所有距离继电器的设置。已使用动态偶发性分析工具(DCAT)在改良的IEEE 300系统上对计算出的zone-3设置进行了测试。