首页> 外文会议>Chinese Automation Congress >An estimation method of main-circuit insulation test for UHV GIS equipment
【24h】

An estimation method of main-circuit insulation test for UHV GIS equipment

机译:特高压GIS设备主电路绝缘试验的估算方法

获取原文

摘要

This paper presents an electrical parameter estimation method of the main-circuit insulation test for 1100kV gas insulated switchgear (GIS) equipment in order to realize the rationality of the test segmentation, equipment selection and parameter matching. First, the test method of main-circuit insulation is given. Then, the methods of estimating test capability of the variable-frequency series-resonant (VFSR) device with or without parallel compensation are presented considering the limitation of electrical frequency and equipment capacity. Next, a method how to estimate electrical parameters of the main-circuit insulation test of the ultra-high voltage (UHV) GIS when specifying test range is proposed. Finally, an example of UHV GIS main-circuit insulation test is given, to estimate the test capability of VFSR device and to verify the accuracy of the electrical variables estimation method. The estimation method can accurately evaluate the test capability of VFSR device and realize the accurate estimation of the electrical parameters when specifying test range, which provides a reliable reference for the test segmentation and equipment selection of the UHV GIS main-circuit insulation test.
机译:为了实现测试分段,设备选择和参数匹配的合理性,本文提出了一种用于1100kV气体绝缘开关设备(GIS)设备主电路绝缘测试的电参数估计方法。首先,给出了主电路绝缘的测试方法。然后,考虑了电频率和设备容量的局限性,提出了估计带或不带并联补偿的变频串联谐振(VFSR)设备测试能力的方法。接下来,提出了一种在指定测试范围时如何估算超高压GIS主电路绝缘测试电气参数的方法。最后,给出了特高压GIS主电路绝缘测试的例子,以评估VFSR设备的测试能力,并验证电变量估计方法的准确性。该估计方法可以准确地评估VFSR装置的测试能力,并在指定测试范围时实现对电气参数的准确估计,为特高压GIS主电路绝缘测试的测试分段和设备选择提供可靠的参考。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号