Hall Effect flow sensor YF-S201 is one of the most common, inexpensive, reliable and accurate flow sensor used in many applications for liquid flow rate measurement. The accuracy of the sensor is due to the linear relationship between the sensor pulse frequency and the flowrate. However, there are various factors that could affect the calibration model, one of them being the attached pipe size configuration. The present work investigates how the Hall Effect sensor calibration curve parameters are affected by the externally attached pipe diameters. The result shows that as the attached pipe size become smaller than the internal diameter of the sensor, the slope and intercept of the calibration curve is found to decrease and increase respectively. This means that the slope of 7.5 Hz per liter per minute (calibration factor) as specified by the by manufacturer of YF-S201 Hall Effect flow sensor cannot be used for higher accuracy requirement when the externally attached pipe size is smaller than the sensor internal diameter.
机译:霍尔效应流量传感器YF-S201是最常见,便宜,可靠和准确的流量传感器之一,在许多用于液体流量测量的应用中使用。传感器的精度取决于传感器脉冲频率与流量之间的线性关系。但是,有多种因素可能会影响校准模型,其中之一是所连接的管道尺寸配置。本工作研究了霍尔效应传感器校准曲线参数如何受到外部连接的管道直径的影响。结果表明,当所连接的管道尺寸变得小于传感器的内径时,发现校准曲线的斜率和截距分别减小和增大。这意味着当外部连接的管道尺寸小于传感器内径时,YF-S201霍尔效应流量传感器的制造商指定的每分钟每分钟7.5 Hz的斜率(校准系数)不能用于更高的精度要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号