Monitoring system was designed by using the voltage sensors and the current sensors that had been calibrated. Data acquisition system was integrated with Excel by using Visual Basic program. The system design used Atmega 8 microcontroller connected to a laptop / PC via Ethernet WIZ107SR and Netgear router. The accuracy of the photovoltaic panel output parameter reading was determined by the accuracy of the reading of the current sensors and the voltage sensors used in the monitoring system. The difference in voltage and current sensors reading between the measurement of monitoring system and multimeter measurement was 0.08 Volt and 0.02 Ampere. The percentage of reading error of voltage sensors and current sensors between the monitoring system measurement and multimeter measurement was 0.69% and 5%. The accuracy of the voltage sensors reading was 99.31% and the current sensors was 95%.
机译:通过使用已校准的电压传感器和电流传感器来设计监视系统。利用Visual Basic程序将数据采集系统与Excel集成在一起。系统设计使用了通过以太网WIZ107SR和Netgear路由器连接到笔记本电脑/ PC的Atmega 8微控制器。光伏电池板输出参数读数的准确性取决于监视系统中使用的电流传感器和电压传感器的读数准确性。监视系统的测量值与万用表测量值之间的电压和电流传感器读数差异为0.08伏特和0.02安培。在监视系统测量和万用表测量之间,电压传感器和电流传感器的读取误差百分比为0.69%和5%。电压传感器的读取精度为99.31%,电流传感器为95%。