The authors have evaluated the possibility of deterioration diagnosis of Oil-filled (OF) cable systems by PD measurement so far. In our previous studies, we confirmed continuous occurrence of PDs even under the design electric field of 275 kV OF cables. Also we confirmed the progress of intermittent occurrence of PDs to continuous one by repeated superimpositions of lightning impulse voltage corresponding to switching surge. However, correlation between PD characteristics and internal conditions of the oil gap defect was not obtained. Therefore, in this study, we experimentally investigated the effects of the switching impulse voltage superimposition that can occur in practical operation of 275 OF cable systems on PD characteristics and we observed the conditions inside the oil gap defect by a CCD camera.
机译:到目前为止,作者已经评估了通过PD测量诊断充油(OF)电缆系统的可能性。在我们以前的研究中,我们确认即使在275 kV OF电缆的设计电场下,PD也会连续发生。通过重复叠加对应于开关浪涌的雷电冲击电压,我们也证实了PD间歇性地发生到连续的过程。然而,未获得PD特性与油隙缺陷的内部条件之间的相关性。因此,在本研究中,我们通过实验研究了275 OF电缆系统的实际操作中可能发生的开关脉冲电压叠加对PD特性的影响,并通过CCD摄像机观察了油隙缺陷内部的情况。