Glazed glass cap and pin insulators that have been removed from the transmission line, have electrical characteristics ensuring them to be reused and reinstalled on lower voltage distribution level lines. The electrical properties determination involving insulator resistance, self-capacitance, corona inception voltage and flashover voltage were measured using AC high voltage generating unit. The advantage of this paper is that it presents, an effective new technique to select aged glazed glass insulator based on measured characteristics, in combination with likelihood of flashover occurrence and compatibility factor, making I-type string insulator design more deterministically and particularly for 33kV distribution line application. Using technique employing coefficient of compatibility, it was found that transmission line glazed glass cap and pin insulator can be recycled, selected and reused for distribution line insulation application.
机译:已从传输线上卸下的玻璃盖和针形绝缘子具有电气特性,可确保将其重新使用并重新安装在较低电压分布水平的线路上。使用交流高压发生装置测量涉及绝缘子电阻,自电容,电晕起始电压和闪络电压的电性能测定。本文的优势在于,它提出了一种有效的新技术,该技术可根据测得的特性来选择老化的玻璃绝缘子,并结合发生跳火的可能性和相容性因素,从而使I型串形绝缘子的设计更具确定性,尤其是对于33kV配电行应用程序。使用相容系数的技术,发现传输线釉面玻璃瓶盖和插脚绝缘子可以回收,选择和再用于配电线路绝缘应用。