Ultra-high molecular weight polyethylene samples were submitted to dynamicalcompressive test in a split Hopkinson Pressure Bar. Three thickness/diameter ratio (0.11,0.44 and 0.64) and two strain rates (3250 s-1 and 6500 s-1) were used to understand howthe test set-up influences the stress equilibrium and the constancy of strain rate duringthe impact. Concepts of stress equilibrium, constancy of strain rate, dynamical stressstraincurves and dynamical mechanical properties of the material were evaluated. Allstudied samples achieved stress equilibrium, but the samples with smaller ratio achievedit more easily. Nevertheless, samples with the smallest ratio were not able to achievestrain rate constancy. Additionally, dynamical stress-strain curves were plotted toinvestigate the mechanical properties of this material at high strain rates. T-tests pointedout that the properties are controlled by the strain rate rather than by the specimen’sthickness/diameter ratio.
机译:超高分子量聚乙烯样品提交到动态 拆分霍普金森压力棒中的压缩试验。三厚/直径比(0.11, 0.44和0.64)和两个应变率(3250 S-1和6500 S-1)用于了解如何 测试设定影响应力平衡和应变率的恒定期间 影响。应力平衡的概念,应变率的恒定,动态应力施用 评价材料的曲线和动力学机械性能。全部 研究了样品实现了应力平衡,但达到较小比率的样品 它更容易。然而,具有最小比率的样品无法实现 应变率恒定。另外,绘制了动态应力 - 应变曲线 以高应变率研究该材料的机械性能。 T-Tests指向 出于该物业由应变率而不是由标本的控制来控制 厚度/直径比。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号