Limits of the ON-OFF technique for the assessment of cathodic protection of buried pipeline

机译:开-关技术在埋地管道阴极保护评估中的局限性

获取原文

摘要

The general criterion used to verify the cathodic protection (CP) condition of a structure is based on the IR-free potential measurement, in compliance with the protection criteria provided by international standards. The measurement techniques to eliminate ohmic drop are based on the reduction of the distance between reference electrode and structure (local or fixed reference electrode, Luggin capillary and potential probes) or on the interruption of the circulating current (ON-OFF technique in impressed current CP systems). Laboratory tests were carried out on cathodically protected carbon steel specimens in order to evaluate the effectiveness of ON-OFF potential technique for the assessment of CP condition. The limitations of the OFF-potential measurement are discussed: the technique is not reliable in overprotection condition, with the risk to underestimate the problems involved in overprotected buried pipes (cathodic disbonding, hydrogen embrittlement of susceptible steels, AC-induced corrosion). The effect of the presence of a low-pass filter in the electrical circuit of the data acquisition system on OFF-potential measurement is discussed.
机译:用于验证结构的阴极保护(CP)条件的一般标准是基于无IR电位测量的,符合国际标准提供的保护标准。消除欧姆降的测量技术基于参比电极与结构(局部或固定参比电极,鲁金毛细管和电势探针)之间距离的减小或循环电流的中断(外加电流CP中的开-关技术)系统)。在阴极保护的碳钢样品上进行了实验室测试,以评估采用开-关电位技术评估CP条件的有效性。讨论了OFF电位测量的局限性:该技术在过度保护条件下不可靠,有可能低估了过度保护的地下管道所涉及的问题(阴极脱胶,易感钢的氢脆,交流感应腐蚀)。讨论了数据采集系统电路中低通滤波器的存在对OFF电位测量的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号