In this work the corrosion rate of UNS K12000 (DIN 17100 ST 52) low-alloy structural steel in monoethanolamine (MEA) solution was studied. The corrosion testing was mainly performed on a rotating disc electrode, and electrochemical impedance was used to estimate the corrosion rate. The parameters studied were rotation rate, influence of oxygen and degradation of the MEA. The results shows a significant increase in the corrosion rate when oxygen was introduced to the system, especially when the rotation rate was high. The corrosion also increased when the MEA solution was degraded.
机译:在这项工作中,研究了UNS K12000(DIN 17100 ST 52)低合金结构钢在单乙醇胺(MEA)溶液中的腐蚀速率。腐蚀测试主要在转盘电极上进行,电化学阻抗用于估算腐蚀速率。研究的参数是转速,氧气的影响和MEA的降解。结果表明,当向系统中引入氧气时,腐蚀速率显着提高,特别是在转速高的情况下。当MEA溶液降解时,腐蚀也增加。